Play Video
1
EEVblog #365 - ESR Meter Bad Cap Monitor Repair
EEVblog #365 - ESR Meter Bad Cap Monitor Repair
::2012/10/05::
Play Video
2
Esr Meter MESR100 v2 Hands on look at a low priced Equivalent series resistance meter.
Esr Meter MESR100 v2 Hands on look at a low priced Equivalent series resistance meter.
::2013/06/30::
Play Video
3
Review: Peak Atlas ESR70 Capacitance and ESR meter
Review: Peak Atlas ESR70 Capacitance and ESR meter
::2013/01/30::
Play Video
4
Low cost ESR Meter review
Low cost ESR Meter review
::2013/09/12::
Play Video
5
ESR70 & Blue ESR meters, comparison, features and differences
ESR70 & Blue ESR meters, comparison, features and differences
::2013/11/21::
Play Video
6
Using an ESR Meter to Determine the
Using an ESR Meter to Determine the 'Health' of Electrolytic Capacitors in Guitar Amplifiers
::2013/07/16::
Play Video
7
MESR-100 ESR Meter Review and Teardown
MESR-100 ESR Meter Review and Teardown
::2014/08/21::
Play Video
8
DIY ESR Meter
DIY ESR Meter
::2012/11/29::
Play Video
9
Bob Parker
Bob Parker's Blue ESR Meter by AnaTek Corp Testing and Assembly
::2013/08/31::
Play Video
10
Китайский прибор для измерения ESR электролитических конденсаторов - Обзор
Китайский прибор для измерения ESR электролитических конденсаторов - Обзор
::2014/01/15::
Play Video
11
Postbag #9: Component Tester, USB Dinky, 3V Pump, Ferrite Rings
Postbag #9: Component Tester, USB Dinky, 3V Pump, Ferrite Rings
::2014/07/12::
Play Video
12
ESR meter selfmade
ESR meter selfmade
::2010/10/09::
Play Video
13
Homemade ESR meter!! (WHHOOOOO!!)
Homemade ESR meter!! (WHHOOOOO!!)
::2012/05/13::
Play Video
14
DIY Arduino Esr Meter Shield - Part 1: Intro & Demo
DIY Arduino Esr Meter Shield - Part 1: Intro & Demo
::2013/04/22::
Play Video
15
Seeburg SHP Amp Capacitor Replacement using Atlas ESR Meter for Recapping
Seeburg SHP Amp Capacitor Replacement using Atlas ESR Meter for Recapping
::2013/01/14::
Play Video
16
ESR Meter Prac
ESR Meter Prac
::2012/11/22::
Play Video
17
Low cost ESR Meter 2501A
Low cost ESR Meter 2501A
::2014/02/24::
Play Video
18
My ESR Meter project from 2006
My ESR Meter project from 2006
::2011/05/20::
Play Video
19
Why use an ESR (Equivalent Series Resistance) meter?
Why use an ESR (Equivalent Series Resistance) meter?
::2014/03/02::
Play Video
20
Equivalent Series Resistance (ESR) Meter - Test Capacitors
Equivalent Series Resistance (ESR) Meter - Test Capacitors
::2011/02/23::
Play Video
21
ESR Meter Compared To General Radio (Genrad) 1650-A Impedance Bridge
ESR Meter Compared To General Radio (Genrad) 1650-A Impedance Bridge
::2013/07/22::
Play Video
22
ESR  METER Analog2011  TRABAJANDO7
ESR METER Analog2011 TRABAJANDO7
::2012/03/19::
Play Video
23
ESR Meter.avi
ESR Meter.avi
::2011/05/01::
Play Video
24
ESR meter, great for detecting bad caps
ESR meter, great for detecting bad caps
::2012/01/19::
Play Video
25
ESR Meter - Medidor de ESR (Equivalent Series Resistance)
ESR Meter - Medidor de ESR (Equivalent Series Resistance)
::2012/03/22::
Play Video
26
Simple LCD display ESR Meter
Simple LCD display ESR Meter
::2013/11/13::
Play Video
27
464-ESR METER PROYECT NE555 Y TLC271CP
464-ESR METER PROYECT NE555 Y TLC271CP
::2014/08/09::
Play Video
28
Измеритель емкости и ЭПС конденсаторов. ESR meter. Дополнение.
Измеритель емкости и ЭПС конденсаторов. ESR meter. Дополнение.
::2013/09/26::
Play Video
29
Homemade ESR Meter
Homemade ESR Meter
::2014/04/22::
Play Video
30
Neoteo ESR meter
Neoteo ESR meter
::2011/09/08::
Play Video
31
Product Spotlight: ESR Meter
Product Spotlight: ESR Meter
::2011/11/02::
Play Video
32
COMPROBADOR CONDENSADORES CASERO Comprobador  Resistencia Serie Condensadores.  E.S.R.  meter
COMPROBADOR CONDENSADORES CASERO Comprobador Resistencia Serie Condensadores. E.S.R. meter
::2011/11/17::
Play Video
33
RLC/ESR Meter based on stm32f100
RLC/ESR Meter based on stm32f100
::2013/09/11::
Play Video
34
How to self test and calibrate Transistor tester ESR Meter
How to self test and calibrate Transistor tester ESR Meter
::2014/09/07::
Play Video
35
esr meter, посылка из украины.
esr meter, посылка из украины.
::2013/12/09::
Play Video
36
DIY Arduino Esr Meter Shield - Part 3:  Arduino Shield Setup & Calibration
DIY Arduino Esr Meter Shield - Part 3: Arduino Shield Setup & Calibration
::2013/05/06::
Play Video
37
Bennys Lab: ESR-Meter
Bennys Lab: ESR-Meter
::2014/09/22::
Play Video
38
Измеритель емкости и ЭПС конденсаторов. ESR meter.
Измеритель емкости и ЭПС конденсаторов. ESR meter.
::2013/05/21::
Play Video
39
ESR Meter
ESR Meter
::2012/04/05::
Play Video
40
esr meter Project Alemanialive.
esr meter Project Alemanialive.
::2011/12/23::
Play Video
41
Lynx - Bob Parkers Digital ESR Capacitor Meter Versus Creatronica Analog ESR Meter
Lynx - Bob Parkers Digital ESR Capacitor Meter Versus Creatronica Analog ESR Meter
::2012/10/28::
Play Video
42
esr meter project27,28,29-Proyect Unico -gsanchez3000cu@gmail.com
esr meter project27,28,29-Proyect Unico -gsanchez3000cu@gmail.com
::2011/12/23::
Play Video
43
Capacitor ESR test w/o ESR meter
Capacitor ESR test w/o ESR meter
::2011/09/18::
Play Video
44
Blue ESR meter short
Blue ESR meter short
::2013/03/15::
Play Video
45
LCM3 ESR Meter
LCM3 ESR Meter
::2012/06/10::
Play Video
46
Blue ESR
Blue ESR
::2013/01/23::
Play Video
47
ESR измеритель. Покупка на ебей. Распаковка. Обзор
ESR измеритель. Покупка на ебей. Распаковка. Обзор
::2014/02/23::
Play Video
48
ESR METER DIGITAL
ESR METER DIGITAL
::2014/09/05::
Play Video
49
esr meter
esr meter
::2012/05/24::
Play Video
50
ESR METER SERVITEC POP
ESR METER SERVITEC POP
::2011/08/30::
NEXT >>
RESULTS [51 .. 101]
From Wikipedia, the free encyclopedia
Jump to: navigation, search
This article is about an instrument for measuring an electronic parameter. For a physiological medical measurement, see Erythrocyte sedimentation rate.

An ESR meter is a two-terminal electronic measuring instrument designed and used primarily to measure the equivalent series resistance (ESR) of real capacitors; usually without the need to disconnect the capacitor from the circuit it is connected to. Most ESR meters work by applying voltage pulses to the capacitor under test which are too short to appreciably charge it; any voltage appearing across the capacitor is due to ohmic drop across the ESR. Measuring ESR can also be done by applying an alternating voltage at a frequency at which the capacitor's reactance is negligible, in a voltage divider configuration.

A standard measurement bridge, and many LCR and Q meters, can also measure ESR accurately, in addition to many other circuit parameters. The dedicated ESR meter is a relatively inexpensive special-purpose instrument of modest accuracy, used mainly to identify capacitors with unacceptably large ESR and sometimes to measure other low resistances; measurements of other parameters cannot be made.

Other types of meter used for routine servicing, including normal capacitance meters, cannot be used to measure a capacitor's ESR, although a few combined meters are available which measure both ESR and out-of-circuit capacitance. A standard (DC) milliohmmeter cannot be used to measure ESR, because a steady direct current cannot be passed through the capacitor.

Most ESR meters can also be used to measure non-inductive low-value resistances, whether or not associated with a capacitor; this leads to a number of additional applications described below.

Need for ESR measurement[edit]

Aluminium electrolytic capacitors have a relatively high ESR that increases with age, heat, and ripple current; this can cause the equipment using them to malfunction. In older equipment, this tended to cause hum and degraded operation; modern equipment, in particular switch-mode power supplies, is very sensitive to ESR, and a capacitor with high ESR can cause equipment to malfunction or cause permanent damage requiring repair, typically by causing power supply voltages to become excessively high.[1] This type of capacitor is very often used because it is inexpensive and has a very high capacitance per unit volume or weight; typically, these capacitors have capacitance from about one microfarad to tens of thousands of microfarads.

Capacitors with faults leading to high ESR often bulge and leak, making them easy to identify visually; however, capacitors that appear visually perfect may still have high ESR, detectable only by measurement.

Precise measurement of ESR is rarely necessary, and any usable meter is adequate for troubleshooting. Where precision is required, measurements must be taken under appropriately specified conditions, because ESR varies with frequency, applied voltage, and temperature. A general-purpose ESR meter operating with a fixed waveform is unlikely to be suitable for precise laboratory measurements.

Principles of operation[edit]

Most ESR meters work by discharging a real electrolytic capacitor (essentially equivalent to a perfect capacitor in series with an unwanted resistance, the ESR) and passing an electric current through it for a short time, too short for it to charge appreciably. This will produce a voltage across the device equal to the product of the current and the ESR plus a negligible contribution from a small charge in the capacitor; this voltage is measured and its value divided by the current (i.e., the ESR) shown in ohms or milliohms on a digital display or by the position of a pointer on a scale. The process is repeated tens or hundreds of thousands of times a second.

Alternatively an alternating current at a frequency high enough that the capacitor's reactance is much less than the ESR can be used. Circuit parameters are usually chosen to give meaningful results for capacitance from about one microfarad up, a range that covers typical aluminium capacitors whose ESR tends to become unacceptably high.

The ESR considered acceptable depends upon capacitance (larger capacitors usually have lower ESR), and may be read from a table of "typical" values, or compared with a new component. In principle, the manufacturer's upper limit specification for ESR can be looked up in a datasheet, but this is usually unnecessary. When a capacitor whose ESR is critical degrades, power dissipation through the higher ESR usually causes a rapid and large runaway increase, so go/no-go measurement is usually good enough as the ESR rapidly moves from a clearly acceptable to a clearly unacceptable level; an ESR of over a few ohms (less for a large capacitor) is unacceptable.

In a practical circuit, the ESR will be much lower than any other resistance in parallel with the capacitor, so it is not necessary to disconnect the component, and an in-circuit measurement can be made. Practical ESR meters use a voltage too low to switch on any semiconductor junctions that may be present in the circuit, which might present a low "on" impedance that would interfere with measurements.

It is easy to check ESR well enough for troubleshooting by using an improvised ESR meter comprising a simple square-wave generator and oscilloscope, or a sinewave generator of a few tens of kilohertz and an AC voltmeter, using a known good capacitor for comparison, or using a little mathematics.[2] A professional ESR meter is more convenient for checking multiple capacitors in rapid succession on a crowded board.

Other uses[edit]

An ESR meter is more accurately described as a pulsed or high-frequency AC milliohmmeter (depending upon type), and it can be used to measure any low resistance. Depending upon the exact circuit used, it may also be used to measure the internal resistance of batteries (many batteries end their useful life largely due to increased internal resistance, rather than low EMF. However, an ESR meter with back-to-back protective diodes across its input cannot be used to measure batteries), contact resistance of switches, the resistance of sections of printed circuit (PCB) track, etc.

While there are specialised instruments to detect short-circuits between adjacent PCB tracks, an ESR meter is useful because it can measure low resistances while injecting a voltage too low to confuse readings by switching on semiconductor junctions in the circuit. An ESR meter can be used to find short-circuits, even finding which of a group of capacitors or transistors connected in parallel by printed circuit tracks or wires is short-circuited. Many conventional ohmmeters and multimeters are not usable for very low resistances, and those that are often use too high a voltage, risking damage to the circuit being tested.

Tweezer probes are useful when test points are closely spaced, such as in equipment made with surface mount technology. The tweezer probes can be held in one hand, leaving the other hand free to steady or manipulate the equipment being tested.

Limitations[edit]

  • An ESR meter does not measure the capacitance of a capacitor; the capacitor must be disconnected from the circuit and measured with a capacitance meter (or a multimeter with this capability). Excessive ESR is far more likely to be an identified problem with aluminium electrolytics rather than out-of-tolerance capacitance, which is rare in capacitors with acceptable ESR.
  • A faulty short-circuited capacitor will incorrectly be identified by an ESR meter as having ideally low ESR, but an ohmmeter or multimeter can easily detect this case, which is much rarer in practice than high ESR. It is possible to connect the test probes to an ESR meter and ohmmeter in parallel to check for both shorts and ESR in one operation; some meters both measure ESR and detect short-circuits.
  • ESR may depend upon operating conditions (mainly applied voltage, temperature); a capacitor which has excessive ESR at operating temperature and voltage may test as good if measured cold and unpowered. Some circuit faults due to such intermittent capacitors can be identified by using freeze spray; if cooling the capacitor restores correct operation, it is faulty.
  • An ESR meter may be damaged by connection to a capacitor with significant voltage across it, either because of residual stored charge or in a live circuit. Protective diodes across the input will minimise this risk, but then the meter can no longer be used to measure battery internal resistance.
  • When an ESR meter is used as a milliohmmeter, any significant inductance present between the test probes will make measurements meaningless. For example, an ESR meter is unsuitable for measuring the resistance of transformer windings because of their inductive characteristics. This effect is significant enough that test probes with coiled cords should not be used due to their inductance.

See also[edit]

References[edit]

  1. ^ Example of high-ESR capacitors causing voltages to rise in a circuit and destroy components. High ESR capacitors cause "5V dropping quite low and causing every other voltage to go sky high (and doing things like frying the HDD with upwards of 15V rather than 12V, and frying the tuning agc transistor with upwards of 36V instead of 30V)."
  2. ^ Stephen M. Powell (2000). "99 cent ESR test adapter". Retrieved 2012-03-10. 
Wikipedia content is licensed under the GFDL License
Powered by YouTube
LEGAL
  • Mashpedia © 2014